| Manufacturer | Delta |
| Model No. | VFD015V43A-2 |
| Description | Elevator with FOC+PG AC Motor Drive |
| Supply Type (Ø) | 3 | |
| Voltage Class | 440V | |
| HP | 2 | |
| KW | 1.5 | |
| Output Frequency (HZ) | 0.00 TO 3600 HZ | |
| Output Current | 4.2 | |
| Braking Chopper | In-Built | |
| Control Mode | V/F, SENSORLESS VECTOR, V/F-PG, FOC-PG, TORQUE-PG | |
| PID/PLC Function | Simple PLC and In-Built High Function PID | |
| PG Close Loop | Yes | |
| Overload Endurance | 150% FOR 1 MINUTE and 200% FOR 2 SEC. | |
| Start-up Torque | 150% AT 0.5 HZ and 200% AT 0.0 HZ (WITH PG) | |
| Comm. |
|
| Manufacturer | Delta |
| Model No. | VFD015V43A-2 |
| Description | Elevator with FOC+PG AC Motor Drive |
| Supply Type (Ø) | 3 | |
| Voltage Class | 440V | |
| HP | 2 | |
| KW | 1.5 | |
| Output Frequency (HZ) | 0.00 TO 3600 HZ | |
| Output Current | 4.2 | |
| Braking Chopper | In-Built | |
| Control Mode | V/F, SENSORLESS VECTOR, V/F-PG, FOC-PG, TORQUE-PG | |
| PID/PLC Function | Simple PLC and In-Built High Function PID | |
| PG Close Loop | Yes | |
| Overload Endurance | 150% FOR 1 MINUTE and 200% FOR 2 SEC. | |
| Start-up Torque | 150% AT 0.5 HZ and 200% AT 0.0 HZ (WITH PG) | |
| Comm. |
|
| Manufacturer | Delta |
| Model No. | VFD037V43A-2 |
| Description | Elevator with FOC+PG AC Motor Drive |
| Supply Type (Ø) | 3 | |
| Voltage Class | 440V | |
| HP | 5 | |
| KW | 3.7 | |
| Output Frequency (HZ) | 0.00 TO 3600 HZ | |
| Output Current | 8.5 | |
| Braking Chopper | In-Built | |
| Control Mode | V/F, SENSORLESS VECTOR, V/F-PG, FOC-PG, TORQUE-PG | |
| PID/PLC Function | Simple PLC and In-Built High Function PID | |
| PG Close Loop | Yes | |
| Overload Endurance | 150% FOR 1 MINUTE and 200% FOR 2 SEC. | |
| Start-up Torque | 150% AT 0.5 HZ and 200% AT 0.0 HZ (WITH PG) | |
| Comm. |
|
| Manufacturer | Delta |
| Model No. | VFD075V43A-2 |
| Description | Elevator with FOC+PG AC Motor Drive |
| Supply Type (Ø) | 3 | |
| Voltage Class | 440V | |
| HP | 10 | |
| KW | 7.5 | |
| Output Frequency (HZ) | 0.00 TO 3600 HZ | |
| Output Current | 18 | |
| Braking Chopper | In-Built | |
| Control Mode | V/F, SENSORLESS VECTOR, V/F-PG, FOC-PG, TORQUE-PG | |
| PID/PLC Function | Simple PLC and In-Built High Function PID | |
| PG Close Loop | Yes | |
| Overload Endurance | 150% FOR 1 MINUTE and 200% FOR 2 SEC. | |
| Start-up Torque | 150% AT 0.5 HZ and 200% AT 0.0 HZ (WITH PG) | |
| Comm. |
|
| Manufacturer | Delta |
| Model No. | VFD110V43A-2 |
| Description | Elevator with FOC+PG AC Motor Drive |
| Supply Type (Ø) | 3 | |
| Voltage Class | 440V | |
| HP | 15 | |
| KW | 11 | |
| Output Frequency (HZ) | 0.00 TO 3600 HZ | |
| Output Current | 24 | |
| Braking Chopper | Optional | |
| Control Mode | V/F, SENSORLESS VECTOR, V/F-PG, FOC-PG, TORQUE-PG | |
| PID/PLC Function | Simple PLC and In-Built High Function PID | |
| PG Close Loop | Yes | |
| Overload Endurance | 150% FOR 1 MINUTE and 200% FOR 2 SEC. | |
| Start-up Torque | 150% AT 0.5 HZ and 200% AT 0.0 HZ (WITH PG) | |
| Comm. |
|
| Manufacturer | Delta |
| Model No. | VFD007V43A-2 |
| Description | Elevator with FOC+PG Motor Drive |
| Supply Type (Ø) | 3 | |
| Voltage Class | 440V | |
| HP | 1 | |
| KW | 0.75 | |
| Output Frequency (HZ) | 0.00 TO 3600 HZ | |
| Output Current | 3 | |
| Braking Chopper | In-Built | |
| Control Mode | V/F, SENSORLESS VECTOR, V/F-PG, FOC-PG, TORQUE-PG | |
| PID/PLC Function | Simple PLC and In-Built High Function PID | |
| PG Close Loop | Yes | |
| Overload Endurance | 150% FOR 1 MINUTE and 200% FOR 2 SEC. | |
| Start-up Torque | 150% AT 0.5 HZ and 200% AT 0.0 HZ (WITH PG) | |
| Comm. |
|
| Manufacturer | Delta |
| Model No. | VFD022V43A-2 |
| Description | Elevator with FOC+PG AC Motor Drive |
| Supply Type (Ø) | 3 | |
| Voltage Class | 440V | |
| HP | 3 | |
| KW | 2.2 | |
| Output Frequency (HZ) | 0.00 TO 3600 HZ | |
| Output Current | 6 | |
| Braking Chopper | In-Built | |
| Control Mode | V/F, SENSORLESS VECTOR, V/F-PG, FOC-PG, TORQUE-PG | |
| PID/PLC Function | Simple PLC and In-Built High Function PID | |
| PG Close Loop | Yes | |
| Overload Endurance | 150% FOR 1 MINUTE and 200% FOR 2 SEC. | |
| Start-up Torque | 150% AT 0.5 HZ and 200% AT 0.0 HZ (WITH PG) | |
| Comm. |
|
| Manufacturer | Delta |
| Model No. | VFD055V43A-2 |
| Description | Elevator with FOC+PG AC Motor Drive |
| Supply Type (Ø) | 3 | |
| Voltage Class | 440V | |
| HP | 7.5 | |
| KW | 5.5 | |
| Output Frequency (HZ) | 0.00 TO 3600 HZ | |
| Output Current | 13 | |
| Braking Chopper | In-Built | |
| Control Mode | V/F, SENSORLESS VECTOR, V/F-PG, FOC-PG, TORQUE-PG | |
| PID/PLC Function | Simple PLC and In-Built High Function PID | |
| PG Close Loop | Yes | |
| Overload Endurance | 150% FOR 1 MINUTE and 200% FOR 2 SEC. | |
| Start-up Torque | 150% AT 0.5 HZ and 200% AT 0.0 HZ (WITH PG) | |
| Comm. |
|
| Manufacturer | Delta |
| Model No. | VFD110V43B-2 |
| Description | Elevator with FOC+PG AC Motor Drive |
| Supply Type (Ø) | 3 | |
| Voltage Class | 440V | |
| HP | 15 | |
| KW | 11 | |
| Output Frequency (HZ) | 0.00 TO 3600 HZ | |
| Output Current | 24 | |
| Braking Chopper | In-Built | |
| Control Mode | V/F, SENSORLESS VECTOR, V/F-PG, FOC-PG, TORQUE-PG | |
| PID/PLC Function | Simple PLC and In-Built High Function PID | |
| PG Close Loop | Yes | |
| Overload Endurance | 150% FOR 1 MINUTE and 200% FOR 2 SEC. | |
| Start-up Torque | 150% AT 0.5 HZ and 200% AT 0.0 HZ (WITH PG) | |
| Comm. |
|
| Manufacturer | Delta |
| Model No. | VFD150V43A-2 |
| Description: | Elevator with FOC+PG AC Motor Drive |
| Supply Type (Ø) | 3 | |
| Voltage Class | 440V | |
| HP | 20 | |
| KW | 15 | |
| Output Frequency (HZ) | 0.00 TO 3600 HZ | |
| Output Current | 32 | |
| Braking Chopper | Optional | |
| Control Mode | V/F, SENSORLESS VECTOR, V/F-PG, FOC-PG, TORQUE-PG | |
| PID/PLC Function | Simple PLC and In-Built High Function PID | |
| PG Close Loop | Yes | |
| Overload Endurance | 150% FOR 1 MINUTE and 200% FOR 2 SEC. | |
| Start-up Torque | 150% AT 0.5 HZ and 200% AT 0.0 HZ (WITH PG) | |
| Comm. |
|