| Manufacturer | Delta |
| Model No. |
VFD220C23A
|
| Description | The Multitasking AC Motor Drive |
| Supply Type (Ø) | 1 OR 3 | |
| Voltage Class | 230V | |
| HP | 30 | |
| KW | 22 | |
| Output Frequency (HZ) | 0.00 TO 600 HZ | |
| Output Current | 90 | |
| Braking Chopper | n-Built | |
| Control Mode | V/F, SENSORLESS VECTOR, V/F-PG, FOC-PG, TORQUE-PG (2) FOC-PG (FOR PM MOTOR) | |
| PID/PLC Function | PLC with Ladder Logic and High Function PID | |
| PG Close Loop | YES | |
| Overload Endurance | 150% FOR 1 MINUTE | |
| Start-up Torque | 150% AT 0.5 HZ and 200% AT 0.0 HZ (WITH PG) | |
| Comm. |
|
| Manufacturer | Delta |
| Model No. | VFD370C23A |
| Description | The Multitasking AC Motor Drive |
| Supply Type (Ø) | 1 OR 3 | |
| Voltage Class | 230V | |
| HP | 50 | |
| KW | 37 | |
| Output Frequency (HZ) | 0.00 TO 600 HZ | |
| Output Current | 146 | |
| Braking Chopper | Optional | |
| Control Mode | V/F, SENSORLESS VECTOR, V/F-PG, FOC-PG, TORQUE-PG (2) FOC-PG (FOR PM MOTOR) | |
| PID/PLC Function | PLC with Ladder Logic and High Function PID | |
| PG Close Loop | YES | |
| Overload Endurance | 150% FOR 1 MINUTE | |
| Start-up Torque | 150% AT 0.5 HZ and 200% AT 0.0 HZ (WITH PG) | |
| Comm. |
|
| Manufacturer | Delta |
| Model No. | VFD550C23A |
| Description | The Multitasking AC Motor Drive |
| Supply Type (Ø) | 1 OR 3 | |
| Voltage Class | 230V | |
| HP | 75 | |
| KW | 55 | |
| Output Frequency (HZ) | 00 TO 600 HZ | |
| Output Current | 215 | |
| Braking Chopper | Optional | |
| Control Mode | V/F, SENSORLESS VECTOR, V/F-PG, FOC-PG, TORQUE-PG (2) FOC-PG (FOR PM MOTOR) | |
| PID/PLC Function | PLC with Ladder Logic and High Function PID | |
| PG Close Loop | YES | |
| Overload Endurance | 150% FOR 1 MINUTE | |
| Start-up Torque | 150% AT 0.5 HZ and 200% AT 0.0 HZ (WITH PG) | |
| Comm. |
|
| Manufacturer | Delta |
| Model No. | VFD900C23A |
| Description | The Multitasking AC Motor Drive |
| Supply Type (Ø) | 1 OR 3 | |
| Voltage Class | 230V | |
| HP | 125 | |
| KW | 90 | |
| Output Frequency (HZ) | 00 TO 600 HZ | |
| Output Current | 346 | |
| Braking Chopper | Optional | |
| Control Mode | V/F, SENSORLESS VECTOR, V/F-PG, FOC-PG, TORQUE-PG (2) FOC-PG (FOR PM MOTOR) | |
| PID/PLC Function | PLC with Ladder Logic and High Function PID | |
| PG Close Loop | YES | |
| Overload Endurance | 150% FOR 1 MINUTE | |
| Start-up Torque | 150% AT 0.5 HZ and 200% AT 0.0 HZ (WITH PG) | |
| Comm. |
|
| Manufacturer | Delta |
| Model No. | VFD015C43A |
| Description | The Multitasking AC Motor Drive |
| Supply Type (Ø) | 3 |
| Voltage Class | 440V |
| HP | 2 |
| KW | 1.5 |
| Output Frequency (HZ) | 0.00 TO 600 HZ |
| Output Current | 4 |
| Braking Chopper | In-Built |
| Control Mode | V/F, SENSORLESS VECTOR, V/F-PG, FOC-PG, TORQUE-PG (2) FOC-PG (FOR PM MOTOR) |
| PID/PLC Function | PLC with Ladder Logic and High Function PID |
| PG Close Loop | YES |
| Overload Endurance | 150% FOR 1 MINUTE |
| Start-up Torque | 150% AT 0.5 HZ and 200% AT 0.0 HZ (WITH PG) |
| Comm. | RS-485 (MODBUS), PROFIBUS, DeviceNet, CANopen, LonWorks Possible with Optional Cards |
| Manufacturer | Delta |
| Model No. | VFD300C23A |
| Description | The Multitasking AC Motor Drive |
| Supply Type (Ø) | 1 OR 3 |
| Voltage Class | 230V |
| HP | 40 |
| KW | 30 |
| Output Frequency (HZ) | 0.00 TO 600 HZ |
| Output Current | 120 |
| Braking Chopper | In-Built |
| Control Mode | V/F, SENSORLESS VECTOR, V/F-PG, FOC-PG, TORQUE-PG (2) FOC-PG (FOR PM MOTOR) |
| PID/PLC Function | PLC with Ladder Logic and High Function PID |
| PG Close Loop | YES |
| Overload Endurance | 150% FOR 1 MINUTE |
| Start-up Torque | 150% AT 0.5 HZ and 200% AT 0.0 HZ (WITH PG) |
| Comm. | RS-485 (MODBUS), PROFIBUS, DeviceNet, CANopen, LonWorks Possible with Optional Cards |
| Manufacturer | Delta |
| Model No. | VFD450C23A |
| Description | The Multitasking AC Motor Drive |
| Supply Type (Ø) | 1 OR 3 |
| Voltage Class | 230V |
| HP | 60 |
| KW | 45 |
| Output Frequency (HZ) | 0.00 TO 600 HZ |
| Output Current | 180 |
| Braking Chopper | Optional |
| Control Mode | V/F, SENSORLESS VECTOR, V/F-PG, FOC-PG, TORQUE-PG (2) FOC-PG (FOR PM MOTOR) |
| PID/PLC Function | PLC with Ladder Logic and High Function PID |
| PG Close Loop | YES |
| Overload Endurance | 150% FOR 1 MINUTE |
| Start-up Torque | 150% AT 0.5 HZ and 200% AT 0.0 HZ (WITH PG) |
| Comm. | RS-485 (MODBUS), PROFIBUS, DeviceNet, CANopen, LonWorks Possible with Optional Cards |
| Manufacturer | Delta |
| Model No. | VFD750C23A |
| Description | The Multitasking AC Motor Drive |
| Supply Type (Ø) | 1 OR 3 |
| Voltage Class | 230V |
| HP | 100 |
| KW | 75 |
| Output Frequency (HZ) | 00 TO 600 HZ |
| Output Current | 255 |
| Braking Chopper | Optional |
| Control Mode | V/F, SENSORLESS VECTOR, V/F-PG, FOC-PG, TORQUE-PG (2) FOC-PG (FOR PM MOTOR) |
| PID/PLC Function | V/F, SENSORLESS VECTOR, V/F-PG, FOC-PG, TORQUE-PG (2) FOC-PG (FOR PM MOTOR) |
| PG Close Loop | YES |
| Overload Endurance | 150% FOR 1 MINUTE |
| Start-up Torque | 150% AT 0.5 HZ and 200% AT 0.0 HZ (WITH PG) |
| Comm. | RS-485 (MODBUS), PROFIBUS, DeviceNet, CANopen, LonWorks Possible with Optional Cards |
| Manufacturer | Delta |
| Model No. | VFD007CV43A |
| Description | The Multitasking AC Motor Drive |
| Supply Type (Ø) | 3 |
| Voltage Class | 440V |
| HP | 1 |
| KW | 0.75 |
| Output Frequency (HZ) | 0.00 TO 600 HZ |
| Output Current | 3 |
| Braking Chopper | In-Built |
| Control Mode | V/F, SENSORLESS VECTOR, V/F-PG, FOC-PG, TORQUE-PG (2) FOC-PG (FOR PM MOTOR) |
| PID/PLC Function | PLC with Ladder Logic and High Function PID |
| PG Close Loop | YES |
| Overload Endurance | 150% FOR 1 MINUTE |
| Start-up Torque | 150% AT 0.5 HZ and 200% AT 0.0 HZ (WITH PG) |
| Comm. | RS-485 (MODBUS), PROFIBUS, DeviceNet, CANopen, LonWorks Possible with Optional Cards |
| Manufacturer | Delta |
| Model No. | VFD022C43A |
| Description | The Multitasking AC Motor Drive |
| Supply Type (Ø) | 3 |
| Voltage Class | 440V |
| HP | 3 |
| KW | 2.2 |
| Output Frequency (HZ) | 0.00 TO 600 HZ |
| Output Current | 6 |
| Braking Chopper | In-Built |
| Control Mode | V/F, SENSORLESS VECTOR, V/F-PG, FOC-PG, TORQUE-PG (2) FOC-PG (FOR PM MOTOR) |
| PID/PLC Function | PLC with Ladder Logic and High Function PID |
| PG Close Loop | YES |
| Overload Endurance | 150% FOR 1 MINUTE |
| Start-up Torque | 150% AT 0.5 HZ and 200% AT 0.0 HZ (WITH PG) |
| Comm. | RS-485 (MODBUS), PROFIBUS, DeviceNet, CANopen, LonWorks Possible with Optional Cards |