- High performance DSP control circuit for ultra high reliability
- High efficiency > 95%
- Protections I/P V & O/P V High-Low,Overload,Time Delay,Single Phase Preventer
- Auto / Manual operation facility
- Plug in type single control card designed for easy serviceability
- High end LCD Display For All Parameters
Products
- Information Technology and Call centers.
- Computer and Micro-Processor Controlled Equipments.
- Sophisticated research instruments used in Scientific, Medical, Agriculture, Educational.and other Research Institutions.
- Processors, Phototypesetters, Photographic Equipments, Photo Copiers and Packaging Industries.
- Medical Equipments, X-Ray Machines, E.C.G. Machines I Monitors, MRI, CT Scans Etc.
- Defence Installations, LPTs. HPTs, Broadcasting and Telecommunications.
- Lifts, Escalators and Elevators.
- Central Air-Conditioning Plants, Processing Plants, Chemical Industries, Textile Industries. . CNC Machines, Laser Machines and Moulding Machines etc.
- Commercial Buildings and Complexes.
- Complexes Hospital and Nursing Homes.
CAPACITY | |||||||||
WATT | 10 KW | 15 KW | 20 KW | 25 KW | 30 KW | 45 KW | 50 KW | 75 KW | 100 KW |
IN PUT | |||||||||
Phase | Three Phase + n ( 4 wire ) | ||||||||
Input Voltage Range | 340V to 480 V or 300 to 480 V or 240 to 480 V or 190 to 480 V | ||||||||
Input Frequency Range | 50Hz ± 5 % | ||||||||
OUT PUT | |||||||||
Nominal Voltage | 415 VAC | ||||||||
Output Voltage Regulation | ± 1 % | ||||||||
Frequency | Same as input | ||||||||
Correction speed | Up to 80 V / sec | ||||||||
Waveform destortion | Nil | ||||||||
Efficiency | 98% | ||||||||
Effect on load PF | Nil | ||||||||
PROTECTION | |||||||||
Voltage cut off | Input, Output high – low | ||||||||
Overload | Electronically | ||||||||
Short circuit | Circuit breaker | ||||||||
Phase | Phase sequnce and Single phase preventor | ||||||||
Overload | > 110 % rated output current | ||||||||
LED indication | On, Trip | ||||||||
GENERAL PARAMETERS | |||||||||
Insulation | Class ” F “ | ||||||||
Working Environment | Temp: -10~40ºC, relative humidity: 30%~90% | ||||||||
Cooling Method | Natural air cooled | ||||||||
Protection Level | IP21 | ||||||||
Dimension W X H X D (MM) | 295 X 520 X 865 | 405 X 670 X 1140 | 495 X 860 X 1470 | ||||||
Weight (Kg) | 82 | 90 | 112 | 130 | 150 | 165 | 175 | 260 | 310 |
- Specially designed high performance DSP. based control circuit for ultra high reliability.
- All Parameter(O/P Voltage I/P voltage high low cut off, time delay, overload) set by front control panel.
- Very low internal impedance.
- High efficiency greater than 95%.
- Fast correction speed( 40 to 80 Volts/Sec).
- Accuracy ± 0.5 to 1 % V from no load to full load.
- Works over wide input frequency range and no waveform distortion.
- Plug in type single control card designed for easy serviceability.
- Auto / Manual operation facility.
- Protection : Input and output v high / low cut off, overload, time delay, single phase preventer,
- Capable to handle 100 % unbalance load.
- Single card used to easy to service.
- Panel control – auto-manual selector switch,increase-deccrese switch to control output v in manual mode,trip bypass,
- History saved up to 20 events.